Energizer PORTABLE GAS DETECTION INSTRUMENT Smoke Alarm User Manual


 
40
CARBON MONOXIDE SPECIFICATIONS
Range:
0 to 500 ppm (for CO 500)
0 to 999 ppm (for CO 999)
Response Time:
T90 < 25 seconds
Operating Temperature Range:
-20 to +50
o
C
(-4 to +122
o
F)
Graphic Display Temperature Range:
-10 to +60
o
C
(+14 to +140
o
F)
Operating Humidity:
15 to 90% RH, Non-Condensing
Recommended Storage Temperature:
0 to 20
o
C
(32 to 68
o
F)
Sensor Accuracy:
±3% of Applied Gas
Linearity:
±3% of Full Scale
Battery Life:
About 100 Hours - Non-Alarming
About 800 Hours in Battery Save Mode
Sensor Cross Sensitivity:
Filtered against H
2
S, 15 ppm: < 0.5 ppm
Filtered against SO
2
, 5 ppm 0 ppm
Nitric Oxide, 35 ppm: < 3 ppm
Nitrogen Dioxide, 5 ppm: - 1 ppm
Chlorine, 1 ppm 0 ppm
Hydrogen, 100 ppm: < 40 ppm
Ethylene, 100 ppm: < 50 ppm
Ethanol, 200 ppm: 0 ppm
Consult Factory for additional information.