Energizer PORTABLE GAS DETECTION INSTRUMENT Smoke Alarm User Manual


 
44
AMMONIA SPECIFICATIONS
Range:
0 to 200 ppm
Response Time:
T90 < 150 seconds
Operating Temperature Range:
-25 to +30
o
C
(-13 to +86
o
F)
Graphic Display Temperature Range:
-10 to +60
o
C
(+14 to +140
o
F)
Operating Humidity:
15 to 90% RH, Non-Condensing
Recommended Storage Temperature:
0 to 20
o
C
(32 to 68
o
F)
Sensor Accuracy:
±3% of Applied Gas
Linearity:
±3% of Full Scale
Battery Life:
About 100 Hours - Non-Alarming
About 800 Hours in Battery Save Mode
Sensor Cross Sensitivity:
Carbon Monoxide at 300 ppm: 0 ppm
Hydrogen Sulfide, 15 ppm: 15 ppm
Sulpher Dioxide, 5 ppm: 4 ppm
Nitric Oxide, 35 ppm: 7 ppm
Nitrogen Dioxide, 5 ppm: 0 ppm
Chlorine, 1 ppm -0.5 ppm
Hydrogen, 200 ppm: 0 ppm
Hydrogen Cyanide, 10 ppm: 0.5 ppm
Hydrogen Chloride, 5 ppm: 0 ppm
Ethylene, 100 ppm: 0 ppm
Consult Factory for additional information.