Energizer PORTABLE GAS DETECTION INSTRUMENT Smoke Alarm User Manual


 
35
Use the “UP” and “SET” push-buttons to enter the correct password. Enter-
ing the incorrect password will display an INCORRECT PASSWORD mes-
sage and allow the user to enter the password again. When the correct
password has been entered, the instrument will display the following screen:
PASSWORD PROTECTION
FOR ADVANCED MENUS
TURN CHANGE
OFF PASSWORD
Depress the “TURN OFF” pushbutton and the instrument will display the
menus as described in section 6.2.
The PASSWORD menu in the CONFIGURATION menu will still require that
the password be properly entered to change the password and/or turn on the
PASSWORD PROTECTION feature after it has been turned off.
To change a password, navigate through the CONFIGURATION menu to the
PASSWORD menu:
PASSWORD PROTECTION
FOR ADVANCED MENUS
TURN CHANGE
ON PASSWORD
Depress the “CHANGE PASSWORD” pushbutton. The following display will
appear with the first digit flashing:
ENTER NEW PASSWORD
0000
UP SET
Depressing the “UP” pushbutton will increase the value of the flashing digit
from 0 through 9. Depressing the “SET” pushbutton will set the digit and
advance to the next digit. For example, we will set the password to “5678”.
When the fourth digit (number 8) has been set by depressing the “SET”
pushbutton, the display will change to the following screen: