Emerson 308014EN Water Heater User Manual


 
10-1
Rosemount Tank Radar REX
Chapter 10 Mechanical Installation
Installation Manual
308014EN, Edition 4
May 2013
10. Mechanical Installation
To achieve precise and trouble free measurement, it is very important to
mount the Radar Tank Gauge correctly on the tank.
Please note that if an ullage plug is required, it has to be installed
separately as there is no ullage plug on the Horn Antenna Gauge or the
Parabolic Antenna Gauge.
Note! Please see the installation drawings for more information. There is a list
of drawings in chapter 13.
10.1 Mounting a Horn Antenna Gauge
The Horn Antenna Gauge must be installed so that there are no pipes or
other obstacles that could prevent the radar beam to reach the bottom
unobstructed. Please refer also to the mechanical installation drawing for
more information on the installation requirements of the Horn Antenna
Gauge and requirements on service space.
10.1.1 Installation Requirements
Maximum height of socket is 330 mm.
Figure 10-1. Installation requirements for Horn Antenna Gauge.
Socket height
maximum 330 mm
Note!
Levels closer than
approximately 850 mm from the
flange, cannot be measured
with the highest accuracy.
3920_SocketReqmts.eps
Note!
For best performance the cone
should end below the socket