DVS -30-2 Indoor Fireplace User Manual


 
Page 28 13369-1-0203
Figure 51
STANDING PILOT WIRING DIAGRAM
Manual Operation
1. Turn ON/OFF/REMOTE switch to REMOTE position.
2. Turn wall thermostat OFF.
3. Turn accessory, FRBC-1, FRBTC-1, FREC-1 or FWS-1, ON.
Appliance is now in the manual mode. You must turn the
appliance ON or OFF with appropriate accessory.
Wall Thermostat Operation
1. Turn the ON/OFF/REMOTE switch to REMOTE position.
2. Turn accessory, FRBC-1, FRBTC-1, FREC-1 or FWS-1, OFF.
3. Turn wall thermostat ON and set appropriate temperature.
Wall thermostat will cycle the appliance ON and OFF.
Installation of Remote Receiver
Place remote receiver on the floor of fireplace behind the louver
as far forward as possible.
Attention: The velcro loop and hook are not necessary in this
installation but can be used to secure remote receiver.
Refer to remote control installation and operating instructions for
more details on remote control.
STANDING PILOT OPERATING INSTRUCTIONS (continued)
Millivolt Control
The valve regulator controls the burner pressure which should be
checked at the pressure test point. Turn captured screw counter
clockwise 2 or 3 turns and then place tubing to pressure gauge
over test point (Use test point “A” closest to control knob). After
taking pressure reading, be sure and turn captured screw clock-
wise firmly to re-seal. Do not over torque. Check for gas leaks.
Millivolt thermopile is self powered gas valve and does not re-
quire 110 volts.
Check System Operation
Millivolt system and all individual components may be checked
with a millivolt meter 0-1000 MV range.