www.desatech.com
112108-01C30
REMEDY
1. Replace ignitor if wire is prop-
erly connected and you have
no spark
2. Using a match, light pilot. If pi-
lot lights turn off pilot and push
piezo again. If pilot lights, an
improper gas/air mixture cause
improper lighting and a longer
purge period is recommended. If
pilot will not light, check gap at
electrode and pilot. Gap should
be 1/8" for strong spark. If elec-
trode is okay, replace pilot
3. Check fuel supply
and contact local propane/LP
supplier if low.
Check for
kinked or bent hoses. Consult
pipe tter or plumber.
1. Defective ignitor
2. Defective pilot or misaligned
electrode at pilot
3. No or low gas pressure
When ignitor button is pressed,
there is no spark at pilot
TROUbLESHOOTING
Continued
REMEDY
1. Check fuel supply
and contact local propane/LP
supplier if low.
Check for
kinked or bent hoses. Consult
pipe tter or plumber.
2. Repeat lighting procedure
several times to purge air from
lines. If unit will still not light,
contact a qualied service and
repair technician
3. Remove debris and dirt, in-
spect and clean other possible
obstructions
4. Replace control valve
5. Contact a qualied technician
to replace pilot line
6. Check that main power is on
and all wire connections are
made correctly to ignition
module
1. No or low gas pressure
2. Air in gas line
3. Construction debris clogging
main orice
4. Control valve knob not
opening
5. Kinked pilot line
6. No power to unit or ignition
module/power transformer is
bad
Ignitor will not spark or burner
will not light
ELECTRONIC IGNITION SYSTEM