Desa (V)CB36P(E) Indoor Fireplace User Manual


 
www.desatech.com
117437-01B20
OPERATING FIREPLACE
Continued
MANUAL LIGHTING
PROCEDURE
1. Remove glass door (see Removing/Replacing
Glass Door, page 17).
2. Follow steps 1 through 8 under Lighting
Instructions, page 19).
3. Press gas control knob and light pilot with
match.
4.
Keep gas control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release gas
control knob. Follow steps 10 through 11 under
Lighting Instructions, page 19).
5. Replace glass door (see Removing/Replacing
Glass Door, page 17).
ELECTRONIC IGNITION
SYSTEM
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information, col-
umn 1, page 19.
2. Turn off all electrical power to the replace.
3. Turn wall switch to the OFF position.
4. Open lower louver panel.
5. Turn equipment shutoff valve clockwise
to the OFF position (see Figure 34).
Do not force.
6. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the oor.
If you smell gas, STOP! Follow “B” in the
safety information, column 1, page 19. If
you don’t smell gas go to the next step.
7.
Turn equipment shutoff valve counterclock-
wise to the ON position. Do not force.
8. Close lower louver panel.
9. Turn on all electric power to the replace.
10. Turn the wall switch to the ON position.
11. Visually locate the pilot. The ignitor should
begin to spark and the main burner should
ignite once ame appears at pilot.
• If lighting the appliance for the rst time
each season, it may take several attempts
before the supply gas can reach the pilot
and main burner.
• If the appliance will not stay lit after sev-
eral attempts, follow the instructions To
Turn Off Gas To Appliance, and call your
service technician or gas supplier.
TO TURN OFF GAS
TO APPLIANCE
1. Turn off the wall switch.
2. Turn off all electric power to the appliance
if service is to be performed.
3. Open lower louver panel.
4. Turn equipment shutoff valve clockwise
to OFF. Do not force.
5. Close lower louver panel.
Figure 35 - Pilot
Pilot
Burner
Ignitor
Sensor
Rod
OPTIONAL WIRELESS
REMOTE OPERATION
Note: The WRC receiver and hand-held remote
control kit must be purchased separately (see
Accessories, page 34). Follow installation in-
structions included with the remote control.
1. Turn equipment shutoff valve to ON posi-
tion. You can now turn the burner on and
off with the hand-held remote unit.
IMPORTANT: Be sure to press the ON/OFF
buttons on the hand-held remote control
unit for up to 3 seconds to assure proper
operation.
2. Press the ON/OFF button to turn the
burner on and off.
Figure 34 - Turning Equipment Shutoff
Valve to the OFF Position
NOTICE: During initial operation
of a new heater, the burning of
residues from the manufacturing
process of the rebox and logs
will produce a paper-burning smell
and orange ames. Open a window
for the rst few hours of operation
to adequately vent this smell.