www.desatech.com
56131-F 19
VENTING INSTALLATION
INSTRUCTIONS
Continued
Figure 32 - Vertical Rigid Venting
Conguration With No Horizontal Run
V = 40' max.
PARTS LIST FOR DESA VENTING
VKR-58 Roof Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Flue Restrictor,
Vertical High Wind Termination,
2' Pipe, 4' Pipe, Wall Firestop,
Storm Collar, Roof Flashing
[0/12 - 6/12], 26 Screws)
VKB-58 Basement Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
Horizontal Square Termination,
4' Pipe, 90° Elbow, 20 Screws)
VKS-58 Snorkel Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
36" Snorkel Termination, 4' Pipe,
1' Pipe, 90° Elbow, 26 Screws)
VKG-58 Ground Floor Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
Horizontal Square Termination,
16 Screws)
P58-48 48" Section Double Wall Pipe,
Galvanized
P58-36 36" Section Double Wall Pipe,
Galvanized
P58-24 24" Section Double Wall Pipe,
Galvanized
P58-12 12" Section Double Wall Pipe,
Galvanized
P58-6 6" Section Double Wall Pipe,
Galvanized
HIGH ALTITUDE INSTALLATION
Your DESA direct-vent fireplace has been
tested and approved for elevations from 0-2,000
feet (USA) and elevations from 0-4,500 feet
(Canada)
Fireplaces for High Altitude (models ending in
-HA) are for installation above 4,000 feet only.
These replaces are equipped with parts specic
for higher altitudes. IMPORTANT: These re-
places can NOT be converted to propane/LP gas.
When installing a non-high altitude replace at an
elevation above 2,000 feet (USA), you may need to
decrease the input rating by changing the existing
burner orice to a smaller size. Reduce input 4%
for each 1,000 feet above sea level. Check with
your local gas company for proper orice size
identication.
When installing this fireplace at an elevation
above 4,500 feet (Canada), check with local
authorities.
IMPORTANT: For horizontal installations
above 2,000 feet, it is recommened that a 12"
extension pipe be added before starter elbow
(see Figure 33).
Figure 33 - Recommended 12" Extension
for High Altitude Installation
45° Starter
Elbow
Note: Install
restrictor into inner
collar of replace
as shown.
45° Starter
Elbow
12"
Extension