Crestron electronic CHV-THSTAT Thermostat User Manual


 
Thermostats Crestron CHV-TSTAT and CHV-THSTAT
4. Device Options
Press the MODE button to access the DEVICE OPTIONS. Press VIEW to select
options. Press the Arrow keys (▲▼) to select the value of the parameter.
MODE
VIEW
T
T
CRESTRON
SETUP: DEVICE OPTS
Network ID:
LCD Contrast
Firmware
Version [0.1] Bld 133
2A
5
Select Network ID
Valid entries are 03 to FE in Hex
to match the network ID set for the
thermostat in SIMPL Windows
Select LCD Screen Contrast
(1 Lighter through 10 Darker)
5. Screen Options
Press the MODE button to access the SCREEN OPTIONS. Press VIEW to select
each option. Press the Arrow keys (▲▼) to select the value of the parameter.
NOTE: The pages in the following setup screen refer to the screens that are seen by
the user when the VIEW key is pressed in the normal operating mode.
Outdoor Page – Temperature/humidity of the outside sensor (if the optional sensor
is installed). May also be imported from Cresnet.
Global Page – Temperature/humidity selection and system status for entire house.
Allows setting of temperature/humidity throughout a multi-thermostat system from a
single location. Must be wired and programmed as part of a Cresnet system.
Remote Function Page(s) – When part of a Cresnet system, remote function pages
allows control of other functions (for example: lights, alarms, etc.). Each of the two
pages has two definable buttons. The up and down keys are set by indirect text
for each page, refer to “CHV-TSTAT and CHV-THSTAT Advanced Symbol” on
page 26.
MODE
VIEW
T
T
CRESTRON
SETUP: SCRN OPTIONS
Disp Global Page?
Disp Outdoor Page?
Disp Rem Func Pg1?
Disp Rem Func Pg2?
Y
Y
Y
Y
Display Global Page?
Yes or No
Display Outdoor Page?
Yes or No
Display Remote Function Pages?
Yes or No
18 Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide – DOC. 8163A