Install the Door Control (Continued)
WIRETHE DOORCONTROLTOTHEGARAGEDOOROPENER
(FIGURE4)
Pre-wired installations:When wiring the door control to the
garage door opener makesure you usethe same wires that are
connectedto the door control.
1. Runthe white and red/white wire from the door control to the
garagedoor opener. Attachthe wire to the wall and ceiling with
the staples (not applicablefor gang box or pre-wired
installations). Do not piercethe wire with the staple as this may
cause a short or an opencircuit.
2. Strip 7/16 inch (11 mm) of insulation from the other end of the
wire nearthe garage door opener.
3. Connectthe wire to the red and white terminals on the garage
door opener.
Figure4 DoorControlConnections
Strip wire 7/16" (11 mm)
ro insert or releasewire, push
in tab with screwdriver tip
INSTALLATION STEP 12
Install TheProtectorSystem®
IMPORTANTINFORMATIONABOUTTHESAFETYREVERSING
SENSOR
Thesafety reversing sensor must be connectedand aligned
correctly before the garagedoor opener will move in the down
direction.
Thesending sensor (with an amber LED)transmits an invisible
light beamto the receiving sensor (with a green LED). If an
obstruction breaksthe light beamwhile the door is closing, the
door will stop and reverseto the full open position, and the
garage door opener lights will flash 10 times.
NOTE:For energy efficiency the garagedoor opener will enter
sleep mode when the door is fully closed. Thesleep mode shuts
the garage door opener down until activated. Thesleep mode is
sequenced with thegarage door opener light bulb; as the light
bulb turns off the sensor LEDswill turn off and wheneverthe
garage door opener lights turn on the sensor LEDs will light. The
garage door opener will not go into the sleep mode until the
garage door opener hascompleted 5 cycles upon power up.
When installing the safety ing sensors checkthe following:
Besure power is NOTconnectedto the garagedoor opener
BEFOREinstalling the safety reversing sensor.
To prevent SERIOUSINJURYor DEATHfrom a closing garage
door:
• Correctly connect and align the safety reversingsensor. This
required safety device MUSTNOTbe disabled.
• Install the safety reversing sensor so beamis NOHIGHER
than 6" (15 cm) abovegaragefloor.
• Sensors are installed insidethe garage,one on either side of
the door.
• Sensors are facing eachother with the lensesaligned and the
receivingsensor lensdoes not receivedirect sunlight.
• Sensors are no more than 6 inches(15 cm) abovethe floor and
the light beam is unobstructed.
Safety Reversing Sensor
6" (15 cm) max. above floor
Invisible Light Beam
Protection Area
Safety Reversing Sensor
6" (15 cm) max. above floor
Facingthe doorfrom inside the garage
23