21020690 B 6500 Disk Array User’s Guide
Chapter 3 Display/Operation Panel
Page 3 - 18 REBUILD
REBUILD
From , use the left/right arrow keys to select the following
functions (see “Menu Structure (3 of 5—Array Info & Rebuild)” on
page 3-8). Use the display/operation panel rebuild options listed below as
described in Chapter 4 of this guide.
Caution If a disk in the array fails, replace the drive and perform a rebuild
as soon as possible. A rebuild can be performed without taking the
array off-line. See Chapter 4 for drive replacement and rebuild
instructions.
REBUILD
DATA
Your selection for the parameter determines whether or not
the data from the failed drive will be reconstructed on the new replacement disk
drive. means the data will be rebuilt; means the data will not be rebuilt.
Caution should always be selected for a data rebuild. Rebuilding
with this selection may result in data corruption and/or inter-
drive parity errors.
REBUILD%
This menu selection allows you to select the percentage of processing time the
array will dedicate to the rebuilding process: , or . The lower
the percentage, the longer the rebuild will take. The default setting is .
START
This selection must be set to before you press SELECT to rebuild a drive.