Ciprico 6500 Air Cleaner User Manual


 
21020690 B 6500 Disk Array User’s Guide
Chapter 2 Installation
Page 2 - 4 Installation Procedure
Step 5.
Set Array
Input Voltage
Switch
Before you connect the array’s power cord to an AC outlet, you must set the
array power supply’s input voltage selection switch to the proper position: the
“115” setting for 100-120 VAC, or the “230” setting for 200-240 VAC.
The power supply’s input voltage selection switch is located between the two
power cord connectors on the rear panel of the array.
Caution If the input voltage selection switch is not in the correct position,
the array power supply will be damaged when power is applied.
Step 6.
Attach Power
Cord
First, verify that the array power ON/OFF switch on the rear panel of the
enclosure is in the OFF position. Then plug the power cord into the appropriate
connector on the rear panel of the array. Plug the other end of the power cable
into the power source.
Caution The standard power cord provided with the array is for use in the
United States and Canada. If necessary, replace the power cord
with one that meets local safety and electrical standards.
Step 7.
Power Up the
Array
Move the power switch on the rear panel of the array enclosure to the ON
position.
Step 8.
Check Array
Status
Observe the display/operation panel for the following start-up displays and
status indications.
Drive Status
At array reset or power-up, the display/operation panel will cycle through a
series of displays that show the status of each drive in the array.
Drives in the array are numbered from right to left, with drive number 1
representing the parity drive and drives 2-9 representing the eight data drives.
9 8 7 6 - 5 4 3 2 - 1
(Drive 1 = Parity Drive)