21
1 Install the door control
Install the Door Control
To preventpossible SERIOUS INJURY orDEATHfromelectrocution:
• Be sure power is NOTconnected BEFORE installing door control.
• ConnectONLY to 12 VOLT lowvoltage wires.
To preventpossible SERIOUS INJURY orDEATHfroma closing garage door:
• Install door control within sightofgarage door,outofreach of children ata minimum heightof5 feet
(1 5 m),and awayfromALL moving partsofdoor.
• NEVER permit children to operate or playwith door control push buttons orremote control
transmitters.
• Activate door ONLY when itcan be seen clearly, is properlyadjusted,and there are no
obstructionsto door travel.
• ALWAYS keep garage door in sightuntil completelyclosed.NEVER permitanyone to crosspath of
closing garage door.
INTRODUCTION
Compatible with MyQ™ enabled accessories,
see page 47.Your garage door opener is
compatible with up to 2 MyQ™ door controls.
NOTE: Older Chamberlain door controlsand
third partyproductsare not compatible.
Install the door control within sightof the door at
a minimum height of5 feet(1.5 m) where small
children cannot reach,and awayfromthe
moving partsofthe door.
NOTE: Your productmay lookdifferentthan the
illustrations.
HARDWARE
Screw
6ABx1-1/2" (2)
Drywall
Anchors (2)
Screw
6-32x1" (2)
NOTE: For gang boxinstallationsitisnot necessaryto drill holesor install the drywall anchors. Use the existing holesin the gang box.
1.1 Strip 7/16 inch (11 mm) ofinsulation from
one end ofthe wire and separate the wires.
7/16"
(11 mm)
1.2 Connectone wire to each ofthe two screws
on the backofthe door control.The wires
can be connected to either screw.
PRE-WIREDINSTALLATIONS:Choose
any two wiresto connect,note which wires
are used so the correctwiresare connected
to the garage door opener in a later step.
1.3 Markthe location ofthe bottommounting
hole and drill a 5/32 inch (4 mm) hole.
Wall
1.4 Install the bottomscrew,allowing 1/8 inch
(3 mm) to protrude from the wall.
DRYWALL
GANG BOX
6ABx1-1-1/2"
6-32x1"
Drywall Anchor