- 6 -
Do not use this fireplace if any part of it has
been under water. Immediately call a qualified
service technician to inspect the fireplace
and replace any part of the control which has
been under water.
Cold climate installation recommendation:
When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory that the outer walls be insulated
to conform to applicable insulation codes.
Non-combustible materials such as brick and tile can be
extended over the outer face of the unit
(Do not cover
louvres or glass door)
. If a Trim Kit is going to be installed,
brick and tile will have to be installed flush with the side of
this appliance.
FINAL FINISHING
HEARTH
A hearth is not mandatory but it is recommended for
aesthetic purposes. We recommend a non-combustible
hearth which does not obstruct louvre opening.
GAS SPECIFICATIONS
MAX. MIN.
INPUT INPUT
MODEL FUEL GAS CONTROL B.T.U.H B.T.U.H.
BHDR36 RN Natural Gas Millivolt Hi/Lo 18,000 12,600
BHDR36 RP Propane Gas Millivolt Hi/Lo 18,000 13,500
CERTIFIED TO
ANSI Z21.88a-1998 / CSA 2.33a-M98
Vented Gas Fireplace Heaters
The installation of your Majestic Fireplace
must conform with local codes, or in the
absence of local codes, with National Fuel
Gas Code, ANSI Z223.1 latest edition, or CAN
1 B1-149.1 and .2 Installation Code.
(EXCEPTION: Do not derate this appliance
for altitude. Maintain the manifold pressure
at 3.5 inches W.C. for Natural Gas and 10
inches W.C. for LP gas.)
GAS INLET & MANIFOLD PRESSURES
Input Minimum
Input Maximum
Manifold Pressure
NATURAL
LP (Propane)
11" wc
13" wc
10" wc
4.5" wc
7" wc
3.5" wc