Vermont Casting BHDR36 Indoor Fireplace User Manual


 
- 30 -
4. Push in gas control knob slightly
and turn clockwise to
"OFF". Do not force.
5. Close control access panel.
10. Push the control knob all the way in and hold.
Immediately light the pilot by repeatedly depressing
the piezo spark ignitor until a flame appears.
Continue to hold the control knob in for about one
(1) minute after the pilot is lit. Release knob and it
will pop back up. Pilot should remain lit. If it goes
out, repeat steps 5 through 8.
If knob does not pop up when released, stop and
immediately call your service technician or gas
supplier.
If after several tries, the pilot will not stay lit, turn
the gas control knob to "OFF" and call your service
technician or gas supplier.
11. Replace glass door.
12. Turn gas control knob to "On" position.
13. For Rn/RP appliances turn the On/Off switch to "On"
positin or set thermostat to desired setting.
14. Turn on all electrical power to the fireplace.
1. STOP! Read the safety information above on this
label
2. Turn off all electrical power to the fireplace.
3. For MN/MP/TN/TP appliances ONLY, go on to Step 4.
For RN/RP appliances turn the On/Off switch to off
position or set thermostat to lowest level.
4. Open control access panel.
5. Push in gas control knob slightly and turn clockwise
to "OFF". Do not force.
6. Wait five (5) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas,
STOP! Follow "B" in the safety information above on
this label. If you don't smell gas, go to the next step.
7. Remove glass door before lighting pilot. (See Glass
Frame Removal in manual).
8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counterclockwise
to "PILOT".
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn
by hand, do not try to repair it, call a qualified service
technician. Applying force or any attempted repair may
result in a fire or explosion.
D. Do not use this fireplace if any part has been under water.
Immediately call a qualified service technician to inspect
the fireplace and to replace any part of the control system
and any gas control which has been under water.
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
A. This fireplace has a pilot which must be lit manually.
When lighting the pilot follow these instructions exactly.
B. BEFORE LIGHTING smell all around the fireplace area for
gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any fireplace.
Do not touch any electric switch
Do not use any phone in your building
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the Fire
Department
TO TURN OFF GAS TO FIREPLACE
LIGHTING AND OPERATING INSTRUCTIONS
1. Turn the On/Off switch to Off position or set the
thermostat to lowest setting.
2. Turn off all electric power to the fireplace if service
is to be performed.
3. Open control access panel.
LIGHTING INSTRUCTIONS
HI
OFF
PILOT
LO
it
P
I
L
O
T
OF
F
O
N
EURO SIT SIT NOVA HONEYWELL
OR