Carrier 33CS400-01 Thermostat User Manual


 
Page 5.1
SECTION 5
Override OperationOverride Operation
Unoccupied
HEAT
COOL
65
55
85
Override
30
HEAT
COOL
65
72
74
Press
OVERRIDE
:
Overriding the Normal OperationOverriding the Normal Operation
The OVERRIDE button may only be used when the Dry Contact has
forced the thermostat into the Unoccupied mode.
Unoccupied Operation - During a Dry Contact forced
unoccupied period pressing the OVERRIDE button will
temporarily force the thermostat into the mode it was in before
the Dry Contact forced it into the Unoccupied mode.
For example: If the thermostat was in the Auto mode and the
Dry Contact forced the thermostat into the Unoccupied mode,
then pressing the OVERRIDE button will force the thermostat
back into the Auto mode.
The remaining override time will be displayed in the upper left
hand corner of the display. The override timer can be set up to a
maximum of four (4:00) hours, in increments of 30 minutes. If the
timer has been set for the maximum time, the next press of the
OVERRIDE button will reset the timer, returning the thermostat to
the Unoccupied mode.
To adjust the setpoints for the Unoccupied mode, see page 15.4.