Burnham 1100-H4 Boiler User Manual


 
9
TABLE 3: BURNHAM VENT SYSTEM AND AIR INTAKE SYSTEM COMPONENTS
TABLE 2: VENT SYSTEM COMPONENTS INCLUDED WITH BOILER
TABLE 4: VENT/AIR INTAKE LENGTH
Vent System Components Part Number
Gasketed Vent Terminal 3” Horizontal
(SCG-3 thru SCG-7)
8110701
Gasketed Vent Terminal 4” Horizontal
(SCG-8 & SCG 9)
8110702
Disc Air Intake - 3”
(SCG-3 & SCG-4)
6116045
Disc Air Intake - 4”
(SCG-5 & SCG-6)
6116044
Air Intake - 5”
(SCG-7 thru SCG-9)
6116063
Vent System Component Part Number
Equivalent
Feet of Pipe
3” Dia. Pipe x 1 Ft 8116296U
1
4” Dia. Pipe x 1 Ft 100176-01
3” Dia. Pipe x 3 Ft 8116298U
3
4” Dia. Pipe x 3 Ft 100177-01
3” Dia. Pipe x 5 Ft 8116300U
5
4” Dia. Pipe x 5 Ft 100178-01
3” Dia. Pipe x Adjustable 8116319U
Equal to
Installed Length
(1.06 TO 1.64)
4” Dia. Pipe x Adjustable 100179-01
3” Dia. 90° Elbow 8116294U
5
4” Dia. 90° Elbow 100180-01
3” Dia. 45° Elbow 8116292U
5
4” Dia. 45° Elbow 100181-01
3” Dia. Horizontal Drain Tee 8116302U
2
4” Dia. Horizontal Drain Tee 100182-01
3” Dia. Vertical Drain Tee 8116304U
4” Dia. Vertical Drain Tee 100183-01
3” Single Wall Thimble 8116116
---
4” Single Wall Thimble 100184-01
3” Double Wall Thimble 8116115
---
4” Double Wall Thimble 100185-01
Intake System Components
(Parts by Others)
Equivalent
Feet of Pipe *
3”, 4”, or 5” ID Pipe x 1 Ft 1
3”, 4”, or 5” ID Pipe x 2 Ft 2
3”, 4”, or 5” ID Pipe x 4 Ft 4
3”, 4”, or 5” ID Pipe x 5 Ft 5
3”, or 4” 90° Elbow 5
3”, or 4” 45° Elbow 5
5” 90° Elbow 6
5” 45° Elbow 6
* Equivalent Feet of Pipe Based on
Standard 4” Smoke Pipe Design
Model
3” Air Intake Pipe
(Equiv. Ft.)
4” Air Intake Pipe
(Equiv. Ft.)
5” Air Intake Pipe
(Equiv. Ft.)
3” Vent Pipe
(Equiv. Ft.)
4” Vent Pipe
(Equiv. Ft.)
Min. Max. Min. Max. Min. Max. Min. Max. Min. Max.
SCG-3 & SCG-4 8 50 --- --- --- --- 8 50 --- ---
SCG-5 & SCG-6 --- --- 8 50 --- --- 8 50 --- ---
SCG-7 --- --- --- --- 8 50 8 50 --- ---
SCG-8 & SCG-9 --- --- --- --- 8 40 --- --- 8 40