Bradford-White Corp 238-48384-00F Water Heater User Manual


 
59
Display of Water Temperature:
Step 1: In Service Mode, Press the “Select” button until “Water Temp” is displayed in the upper right section of
the water heater display. This is the reading for the tank sensor.
To Display Flame Sense Current of the Pilot Flame Sensor:
The pilot flame sense current is available only when the burners are in operation. Step 1: Make sure the
status displays “Heating” or draw enough hot water to start the burners. Step 2: Enter the “Service Mode”
described previously. Step 3: Press the “Select” button until a number value is displayed with “Flame Current”
to the right of the number. The value displayed is in microamps (µA).
SELECT SET
Status
°F
idle
Operational
Wate
r
Temp
SELECT SET
Status
Operational
Flame
Current
Heating
µA