Instruction Manual – Model CF2500/CF3500 Oil Burner
7
Form 6104 BCF-35-R0699
Z
3506
a
Measure dimension from
front (flat) face of head to
end of air tube, as shown.
Z
b
d
c
Figure 5 – Nozzle line assembly in burner
❏❏
❏❏
❏ Set dimension Z
• Replace the rear access door on the
burner, making sure that the adjusting
plate assembly is now securely held in
place.
• Loosen acorn nut d in Figure 5. Slide
the nozzle line and plate assembly un-
til dimension Z in Figure 5 is:
CF2500A/CF2500 1³⁄₄" ± ¹⁄₁₆"
CF3500A (tube KM) 2⁵⁄₈" ± ¹⁄₁₆"
CF3500A (tube KR) 3⁹⁄₁₆" ± ¹⁄₁₆ "
• When dimension Z (from end of air tube
to flat area of front face of head) is cor-
Figure 6 – Adjusting plate assy.
Legend (Figures 5 and 6)
a Adjusting plate assembly
b Spline nut for securing nozzle line
c Bottom acorn nut
d Top acorn nut (for setting dim. Z
only)
e Indicator adjusting plate
f Secondary adjusting plate
g Primary adjusting plate
rectly set, tighten acorn nut d. Verify
that the adjusting plate assembly is
properly seated at the rear access
door, as shown in Figure 5.
• Attach the oil line from the oil valve
to the nozzle line end. Tighten se-
curely.
• Before proceeding, check dimen-
sion Z once again. Loosen acorn nut
d if necessary to reposition the
nozzle line. Once dimension Z is set,
do not loosen acorn nut d again.
For the setting of acorn nut c, refer
to page 12.
❏ Insert burner
• Position the burner in the front of
the appliance and loosely tighten
the nuts on the mounting studs. The
burner should be pitched downward
2° as shown in Figures 3 and 7.
• See Figure 7. Install the pedestal
support kit (recommended) by at-
taching the ³⁄₄" npt flange (item a)
to the bottom of the burner using
the (4) #10 screws provided. Cut and
thread (one end only) a ³⁄₄" pipe
nipple (item b) with length 14.5
inches less than dimension D in Fig-
ure 7. Thread the pipe into the
flange. Then slip the pipe end into
the floor flange (item c).
• Secure the burner to the appliance
by tightening the nuts on the burner
flange mounting studs. Then secure
the pedestal support floor flange set
screw to the pipe.
Figure 7 – Burner installed in appliance front
Legend
H Housing total length — 20"
J Center to bottom of housing — 14¹⁄₂" K Overall housing height — 22³⁄₄"
Measure dimension Z from the flat
surface between (not on) the raised fins.
3507
3508
e
g
d fc
3509
D
H
K
J
a
b
c
1¾"