Beckett CF 2500/ 3500 Burner User Manual


 
Instruction Manual Model CF2500/CF3500 Oil Burner
3
Form 6104 BCF-35-R0699
Warranty
Beckett warrants its equipment to those who
have purchased it for resale, including your
dealer. If you have any problems with your
equipment or its installation, you should
contact your dealer for assistance.
Specifications
Fuels #1 or #2 Fuel Oil
Firing range CF2500A 17.0 - 19.9 GPH
CF2500 17.0 - 25.0 GPH
CF3500A 17.0 - 35.0 GPH
Motor 2 HP 3450 RPM
208/230/60 hz/1-PH std.
13.4 amps @ 230 VAC
Optional voltages:
(60 hz or 50 hz) –
208/230/480/3-PH
Ignition Trans. 120V/12,000V
Housing Cast aluminum
Fuel unit 100 - 300 PSIG
Oil nozzle 45° - 70° solid
Shipping wt. 106 lbs.
Dimensions See Figure 7 (Page 7)
(See NOTICE on opposite page for 50 hz motor applications.)
Agency approvals
Underwriters Laboratories has certified
this burner to comply with ANSI
Standard 296 and has listed it for use
with No. 1 or No. 2 fuel oil as specified
in ASTM D396. State and local
approvals appear on the burner rating
label.
Certified by ULC.
Approved by Commonwealth of
Massachusetts - State Fire Marshall.
Accepted by N.Y.C. M.E.A.
Other approvals may be available and
must be specified at time of order.
Contents
Please . . . read this page first ................ 2
Pre-installation checklist........................... 4
Mount the burner .......................................... 6
Connect fuel line(s)...................................... 8
Wire the burner............................................ 10
Sequence of operation - typical ............ 11
Prepare the burner for start-up............. 11
Start the burner .......................................... 14
Maintenance and service......................... 15
Replacement parts................... Back cover
Before you begin . . .
The following resources will give you additional information
for your installation. We suggest that you consult these
resources whenever possible. Pay particular attention to the
appliance manufacturers instructions.
Appliance manufacturers instructions Always follow
the appliance manufacturers instructions for burner
installation, equipment and setup.
1800OILBURN Becketts technical services hot-line.