Heater Placement Requirements
Heater must be installed on a level surface capable of supporting the heater and vent.
Due to high temperatures, the appliance should be located out of traffic and away from furniture
and draperies.
When placed in a location where the floor to ceiling height is under 7 feet, the installation is
considered an alcove and must meet the following requirements:
The alcove floor to ceiling height must be at least 58 tall
The alcove must not be more than 45 deep before the ceiling returns to 7
The alcove must be at least 46-3/4 wide
The heater must not be placed so the vents below or above the door, along the sides of heater, or
along the back of the heater can become blocked.
This heater may be placed in a bedroom. Please be aware of the large amount of heat this
appliance produces when determining a location.
Floor Protection Requirements
When the stove is installed directly on carpeting, vinyl or other combustible material other
than wood flooring or a high pressure laminate wood floor, the stove must be installed on
a metal or wood protection panel extending the full width and depth of the heater
(Minimum 26-3/4 wide by 19 deep).
Make sure these rubber tipped bolts on each leg
contact the floor (they dampen any noise that may
transmit through the hearth). Do not adjust with
weight on the legs, the rubber tips may tear.