Installation (for qualified installers only) 7
Travis Industries 100-01169_001 4050119
Installation Warnings:
! Failure to follow all of the requirements may result in property damage, bodily
injury, or even death.
! This heater must be installed by a qualified installer who has gone through a
training program for the installation of direct vent gas appliances.
! This appliance must be installed in accordance with all local codes, if any; if not,
follow ANSI Z223.1 and NFPA 54(88).
! In Manufactured or Mobile Homes must conform with Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a
standard is not applicable, the Standard for Manufactured Home Installations,
ANSI/NCSBCS A225.1. This appliance may be installed in Manufactured Housing
only after the home is site located.
! This stove is designed to operate on natural gas or propane (LP).
! All exhaust gases must be vented outside the structure of the living-area.
Combustion air is drawn from outside the living-area structure.
! Notify your insurance company before hooking up this stove.
! The requirements listed below are divided into sections. All requirements must be
met simultaneously. The order of installation is not rigid – the qualified installer
should follow the procedure best suited for the installation.
Packing List
• Propane Conversion Kit
• Log Set
• Glass Latch Tool (to un-latch glass frame)
• Touch-Up Paint
Additional Items Required
• Vent (see “Venting Requirements” for details)
• Gas Line Equipment (shutoff valve, pipe, etc.)
Installation Overview
See "Vent
Requirements"
See "Floor
Protection
Requirements"
See "Gas Line
Installation"
See
"Clearances"