14 Installation (for qualified installers only)
Travis Industries 100-01169_001 4050119
Horizontal Termination with One 90° Elbow
If using a Snorkel Termination (14 or 36) add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.
5 feet
10 feet
15 feet
19' (max)
0 feet
5 feet
0 feet
0 feet
5 feet
10 feet
15 feet
Restrictor Position # 5
NOTE:
Restrictor positions are based
upon lab tests. The ideal
restrictor position may vary
slightly, especially when the
termination is near a
demarkation line.
Restrictor
Position # 1
10 feet
15 feet
20 feet
24 ' (max)
0 feet
5 feet
10 feet
15 feet
20 feet
24 ' (max)
19' (max)
NOTE:
Horizontal sections require a 1/4"
rise every 12" of travel.
NATURAL GAS: Min. 2' Section Required
PROPANE (LP): Min. 3' Section Required