22 Finalizing the Installation (for qualified installers only)
Travis Industries 100-01169_001 4050119
Finalizing the Installation
! Make sure the gas control valve is “OFF” and the heater is cool prior to conducting service.
1 Remove the face and glass (see page 24)
! We recommend you purge the gas line at this time (with the glass removed). This allows gas to be
detected once it enters the firebox, ensuring gas does not build up.
2 Install the log set and coals (see page 26).
3 Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot. Start
the main burner. Leak test all gas joints again.
4 Inspect the pilot flame (see the illustration below). Adjust the pilot flame if necessary.
Pilot Flame Adjustment
Standard
Screwdriver
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.
5 Replace and secure the glass and face (see page 24)