Avalon Stoves Direct Vent Freestanding Stove Stove User Manual


 
Installation (for qualified installers only) 21
Travis Industries 100-01169_001 4050119
Masonry Chimney Conversions (Interior or Standard)
Follow the requirements and use the equipment listed in the illustration below to install this appliance
into an interior masonry chimney.
Maximum vertical rise is 40'
Minimum vertical rise is 10'
The restrictor position should be set to the position that most closely resembles the vent
configuration (see "Approved Vent Configurations" for details). NOTE: because this installation
utilizes non-standard vent, the restrictor position may vary. Carefully monitor the burn characteristics
to verify correct restrictor position.
NOTE
: Certain jurisdictions may not allow this type of installation or may require two co-linear vents be used for
venting through an existing masonry chimney. Check with your local building official before installing.
The entire chimney system must be
air-tight. Make sure to seal the
flashing, clean-out, and thimble
connection, and to inspect the
chimney.
4" Dia. Flex Line
(UL 1777 Gas Liner)
Co-Axial Straight
Lengths
#991 High Wind
Termination
#990 90° Elbow
Flashing (included in
#934 Masonry
Conversion Kit
Make sure the coaxial pipe
maintains a 1 clearance to any
combustible. The vent must be
sealed air-tight.
High-Temp.
Silicone
Connector with Cover
(included in #934 Masonry
Conversion Kit)
Freestanding Masonry Chimney
Standard Masonry Fireplace
Connector (included in #934
Masonry Conversion Kit)
secured and sealed to
block-off plate.
Flashing (included in
#934 Masonry
Conversion Kit)
#991 High Wind
Termination
The entire chimney system must
be air-tight. Seal the connector
cover and inspect the chimney.
Make sure the coaxial pipe
maintains a 1 clearance to any
combustible. The vent must be
sealed air-tight.
High-Temp.
Silicone
4" Dia. Flex Line
(UL 1777 Gas Liner)