Avalon Stoves Direct Vent Freestanding Stove Stove User Manual


 
44 Optional Equipment (for qualified installers only)
Travis Industries 100-01169_001 4050119
3 Attach the rheostat assembly following the directions below.
Disconnect the molex connector
leading to the power cord.
Attach the two molex connectors on the
rheostat wiring harness to the power cord and
the molex connector on the appliance.
Attach the quick-
connect from the
accent light to the
quick-connect on the
rheostat wiring
harness.
Use the included wire nut to connect
the wire leading from the rheostat to
the remaining wire leading from the
accent light.
Slide the rheostat assembly into
place and secure with the
included nuts.
d
e
Make sure all wiring does not contact the
firebox or blower (use wireties if necessary).
a
b
c
4 Restore the firebox to the correct configuration (replace the burners, etc.).