Installation (for qualified installers only) 9
© Travis Industries 4040830 100-01143
Fireplace Placement Requirements
Minimum Framing Dimensions
The fireplace requires a 1/2" space between the fireplace and the framing members (or other
materials) along the sides and back of the fireplace. The stand-offs (and nailing brackets) may
contact the framing members but no material may be placed into the 1/2" space.
Route the electrical line to a position
to the right rear of the fireplace.
Thermostat or Remote
Control Wire (either side)
If using an elbow directly off the fireplace,
the vent will be centered 41-3/4" above
the base of the fireplace.
1/2" Clearance to the front, 0" to the sides, 1" below,
and 2" above the vent to combustibles.
The fireplace enclosure must be a minimum
48" above the base of the fireplace. NOTE:
Do not build into the area above the
fireplace (except for the required framing
members).
20-1/4"
36"
48" Min.
15-1/2"
Firestop
(required)
HINT: We recommend installing the
shaded framing after the fireplace is in
place.
WARNING: A cut-out for the gas line will be
required on the framing. See the dimensions
on page 6 and "Gas Line Connection" for
details.
HINT: we recommend reinforcing the
upper corners of the fireplace opening.
6"
5"
1"
• Fireplace must be installed on a level surface capable of supporting the fireplace and vent
• Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or
carpet)
• This heater may be placed in a bedroom. Please be aware of the large amount of heat this
appliance produces when determining a location.
Clearances
• When installed, walls in front of the fireplace must be a minimum 1" to the side of the
faceplate.
• Due to the high temperature, the heater should be located out of traffic and away from furniture
and draperies.
• Fireplace must be placed so the vents below and above the glass do not become blocked