Installation (for qualified installers only) 7
© Travis Industries 4040830 100-01143
Installation Warnings
• Failure to follow all of the requirements may result in property damage, bodily
injury, or even death.
• This heater must be installed by a qualified installer who has gone through a
training program for the installation of direct vent gas appliances.
• This appliance must be installed in accordance with all local codes, if any; if not,
follow ANSI Z223.1 and NFPA 54(88).
• In Manufactured or Mobile Homes must conform with Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a
standard is not applicable, the Standard for Manufactured Home Installations,
ANSI/NCSBCS A225.1. This appliance may be installed in Manufactured Housing
only after the home is site located.
• The fireplace is designed to operate on natural gas, or propane (LP).
• All exhaust gases must be vented outside the structure of the living-area.
Combustion air is drawn from outside the living-area structure.
• Notify your insurance company before hooking up this fireplace.
• The requirements listed below are divided into sections. All requirements must
be met simultaneously. The order of installation is not rigid – the qualified
installer should follow the procedure best suited for the installation.
Packing List
• Propane Conversion Kit
• Log Set
• Glass Latch Tool (to un-latch glass frame)
Additional Items Required
• Faceplate
• Direct Vent (Simpson Dura-Vent Ph. # 800 835-4429)
• Gas Line Equipment (shutoff valve, pipe, etc.)
• Electrical Equipment (min. 14 gauge, grounded line)