Avalon Stoves 21 DV Fireplace Indoor Fireplace User Manual


 
24 Installation (for qualified installers only)
© Travis Industries 4040830 100-01143
Facing Detail – Drywall Facing
NOTE The facing tucks under the
notch at the front of the fireplace
(3/8 above the base of the
fireplace).
Recommended Order of Installation We
recommend installing the facing (drywall, tile)
under the notch at the front of the fireplace
(a) - then install the sides and top (b and
c)
a
b
c
Top View - Drywall Facing
NOTE: When installed, there must
be a minimum 1/8 gap between
the face and facing.
White Tape Gasket
(attached to fireplace)
Face
Drywall, paneling, or other
facing (combustible or non-
combustible).
Fireplace
1/2"
Nailing Bracket
1/4"
Fireplace
NOTE: The facing should tuck
behind the wall trim, thus
concealing the top of the facing
and the base of the fireplace.
Facing (drywall, paneling, or other
material - combustible or non-
combustible).
NOTE: The fireplace is shifted back
on the shelf to accommodate the
facing thickness.
Side View - Drywall Facing