Avalon Stoves 21 DV Fireplace Indoor Fireplace User Manual


 
12 Installation (for qualified installers only)
© Travis Industries 4040830 100-01143
Gas Line Requirements
MASSACHUSETTS INSTALLATIONS - WARNING:
THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUYMBER OR GAS FITTER WHEN INSTALLED WITHIN
THE COMMONWEALTH OF MASSACHUSETTS.
OTHER MASSACHUSETTS CODE REQUIREMENTS:
Flexible connector must not be longer than 36 inches.
Shutoff valve must be a “T” handle gas cock.
Only direct vent sealed combustion products are approved for bedrooms or bathrooms.
Fireplace dampers must be removed or welded in the open position prior to the installation of a fireplace insert or gas
log.
The gas line must be installed in accordance with all local codes, if any; if not, follow ANSI
223.1 and the requirements listed below.
The fireplace and gas control valve must be disconnected from the gas supply piping during
any pressure testing of that system at test pressures in excess of 1/2 psig. For pressures under 1/2
psig, isolate the gas supply piping by closing the manual shutoff valve.
Leak test all gas line joints and the gas control valve prior to and after starting the fireplace.
Gas Line Location
The gas inlet is located on the left side. It may be re-located to the base of the fireplace (see “Optional Gas
Line Location” on the following page).
The left side gas inlet is
located 2-3/4" above the
base of the fireplace.
1/2" F.P.T.
4"
Gas Line (1/2" M.P.T.)
The base mount gas
inlet is flush with the
base of the fireplace.
NOTE: a 3" diameter hole is required to provide
clearance for the gas inlet screws.
4-1/4"
8-1/4"
1/2" F.P.T.
Gas Line
(1/2" M.P.T.)
Fuel
This fireplace is designed either for natural gas or for propane (but not for both). Check the sticker on the top of
the gas control valve to make sure the correct fuel is used (see illustration on page 4).
Gas Line Connection
Installation must be performed by a qualified installer, service agency or the gas supplier (In Massachusetts
a licensed plumber/gasfitter).
Gas Inlet Pressure
Standard Input Pressure
Natural Gas 7" W.C. (1.74 kPA)
Propane 13" W.C. (2.73 kPA)
If the pressure is not sufficient, make sure the piping used is large enough, the supply regulator is
adequately adjusted, and the total gas load for the residence does not exceed the amount supplied.
The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) should
supply gas at the suggested input pressure listed above. Contact the local gas supplier if the regulator is at
an improper pressure.