Ariston 47-116-17 Boiler User Manual


 
Fasten the boiler in place using the template and anchors supplied
with the unit. It is highly recommended that a spirit level be used to
position the boiler so that it is perfectly level.
For additional information, please consult the instructions contained
in the connection kit and the flue kit.
2.5. MOUNTING THE APPLIANCE
2.6. ELECTRICAL CONNECTION
For safety purposes, have a competent person carefully check the
electrical system in the property, as the manufacturer will not be held
liable for damage caused by the failure to earth the appliance
properly or by anomalies in the supply of power. Make sure that the
residential electrical system is adequate for the maximum power
absorbed by the unit, which is indicated on the rating plate. In
addition, check that the section of cabling is appropriate for the
power absorbed by the boiler.
The boiler operates with alternating current, as indicated in the
technical data table (1.2), where the maximum absorbed power is
also indicated. Make sure that the connections for the neutral and live
wires correspond to the indications in the diagram. The appliance
electrical connections are situated on the reverse of the control panel
(see the servicing manual for further information)
FIG. 2.3
2.7. GAS CONNECTION
The local gas region contractor connects the gas meter to the
service pipe.
If the gas supply for the boiler serves other appliances ensure that an
adequate supply is available both to the boiler and the other
appliances when they are in use at the same time.
Pipe work must be of an adequate size. Pipes of a smaller size than
the boiler inlet connection should not be used.
5
275
In order to allow for access to the interior of the boiler for
maintenance purposes, the boiler must be installed in compliance
with the clearance requirements indicated in the diagram below.
2.4. MINIMUM CLEARANCES
FIG. 2.2
24 MFFI
24 MFFI SYSTEM
IMPORTANT!
In the event that the power supply cable must be changed, replace it
with one with the same specifications. Make the connections to the
terminal board located within the control panel, as follows:
- The yellow-green wire should be connected to the terminal marked
with the earth symbol; make sure to re-use the ferrule mounted on
the other supply cord;
- The blue wire should be connected to the terminal marked “N”;
- The brown wire should be connected to the terminal marked “L”.
Note: The diagrams for the electrical system are indicated in section
2.11.
Warning, this appliance must be earthed.
External wiring to the appliance must be carried out by a qualified
technician and be in accordance with the current I.E.E. Regulations
and applicable local regulations. The Genus range of boilers are
supplied for connection to a 230 V
~
50 Hz supply.
The supply must be fused at 3 A.
The method of connection to the electricity supply must facilitate
complete electrical isolation of the appliance, by the use of a fused
double pole isolator having a contact separation of at least 3 mm in
all poles or alternatively, by means of a 3 A fused three pin plug and
unswitched shuttered socket outlet both complying with BS 1363.
The point of connection to the Electricity supply must be readily
accessible and adjacent to the appliance unless the appliance is
installed in a bathroom when this must be sited outside the
bathroom.