Ariston 47-116-17 Boiler User Manual


 
8
Removing the condensate trap
1. Loosen the union “O” (FIG. 1.22);
2. Remove the condensate trap (FIG. 1.23).
FIG. 1.22
O
Removing the injector
See the section on removing the fan before carring out this
procedure
1. Disconnect all connections from the fan and remove
(F
IG. 124);
2. Remove the four screws “P” (FIG. 125);
3. Unscrew the injector “Q” using a suitable screwdriver
(FIG. 126);
4. Remove the injector (FIG. 127).
Fig. 1.23
Fig. 1.24
Fig. 1.25
P