Ariston 47-116-17 Boiler User Manual


 
25
C1 = FAN
1: Hallsensor power supply 12V (red)
2: Hallsensor ground (blue)
3: Not used
4: Start of coil (black)
5: Hallsensor input (white)
6: End of coil (brown)
C2 = POWER SUPPLY
1: Earth (yellow/green)
2: Earth (yellow/green)
3: Not connected
4: Neutral (blue)
5: Not connected
6: Live (brown)
C3 = CONNECTION TO ROOMSTAT
1: Input - 1
2: Input - 2
C4 = TIMER
1: 3 V output
2: Timer ground
3: Timer output
4: Not connected
C5 = REMOTE CONTROL (Bus+/Bus-)
1: Input/output-1
2: Input/output-2
C6 = SENSOR CONNECTOR
1: Domestic hot water flow switch (grey)
2: Main circuit flow switch (grey)
3: Under floor heating thermostat (grey)
4: Heating flow sensor (grey)
5: Heating return sensor (grey)
6: Domestic hot water sensor (grey)
7: Not used: jumper
8: Outdoor sensor (grey)
9: Domestic hot water flow switch (grey)
10: Main circuit flow switch (grey)
11: Under floor heating thermostat (grey)
12: Flow sensor (grey)
13: Heating sensor (grey)
14: Domestic hot water sensor (grey)
15: Not used: under floor heating
16: Outdoor sensor (grey)
C7 = EQUIPMENT CONNECTIONS
1: Secondary output (optional)
2: Gas valve (white)
3: 3-way valve neutral (white)
4: Pump (white)
5: Ionisation (black)
6: Not connected
7: Ground
8: Pump earth (yellow/green)
9: Secondary output (optional)
10: Gas valve (brown)
11: 3-way valve (domestic hot water) (brown)
12: 3-way valve (heating) (brown)
13: Pump (brown)
14: Not connected
15: Earth
16: Gas valve earth (yellow/green)