Nilfisk-ALTO RS 501 Vacuum Cleaner User Manual


 
USER MANUAL
ENGLISH
RS 501 33015501(3)2008-02 A
11
Hydraulic system data Values
Maximum drive system pressure 250 Bar
Maximum accessory system pressure 120/200 Bar
Hydraulic system oil (at ambient temperature above 10°C) AGIP Arnica 46 (****)
NOTE
If the machine is to be used at ambient temperatures below 10°C, the oil should be replaced with equivalent oil having a
viscosity of 32 cSt. For temperatures below 0°C, use oil with lower viscosity.
(****) See the below hydraulic system oil technical data and reference data tables.
SPECIFICATIONS REFERENCE DATA
AGIP ARNICA 46 32 ISO-L-HV
Viscosity at 40°C mm²/s 45 32 ISO 11158
Viscosity at 100°C mm²/s 7.97 6.40 AFNOR NF E 48603 HV
Viscosity index / 150 157 AISE 127
Flash point COC °C 215 202 ATOS Tab. P 002-0/I
Pour point °C -36 -36 BS 4231 HSE
Density at 15°C kg/l 0.87 0.865 CETOP RP 91 H HV
COMMERCIAL HYDRAULICS
Danieli Standard 0.000.001 (AGIP ARNICA
22, 46, 68)
EATON VICKERS I-286-S3
EATON VICKERS M-2950
DIN 51524 t.3 HVLP
LAMB LANDIS-CINCINNATI P68, P69 and P70
LINDE
PARKER HANNIFIN (DENISON) HF-0
REXROTH RE 90220-1/11.02
SAUER-DANFOSS 520L0463
Climate control system data (optional) Values
Gas type Reclin 134a
Gas quantity 0.8 kg
ENVIRONMENTAL CONDITIONS
In the environment where the machine operates, there must not be any danger of explosion.
To avoid inhaling exhaust gas, the machine must be used only where there is a proper air change.
The machine operates correctly (*) in the following environmental conditions:
Temperature: -10°C to +40°C
Humidity: 30% to 95%
(*) When using the sweeper at a temperature between -10°C and 0°C the dust control system cannot be used; moreover the
water tanks and the dust control system itself must be empty.