Nilfisk-ALTO RS 501 Vacuum Cleaner User Manual


 
USER MANUAL
ENGLISH
RS 501 33015501(3)2008-02 A
23
Maintenance
Running-in
period (after the
fi rst 50 hours)
Every 10
hours or
before use
Every
200
hours
Every
600
hours
Every
1,200
hours
Every
2,400
hours
Long
periods
Diesel engine start-up safety system check (6)
Tyre pressure check
Suction inlet and skirt height and operation check
Side broom position check and adjustment
Engine oil change (7)(8)
Dust control system water fi lter cleaning
Parking brake check
Alternator belt tension check (7)
Climate control system compressor belt tension check (6)
Diesel engine oil fi lter replacement (7)(8)
Fuel fi lter replacement (7)
Nut and screw tightening and leakage check (6) (6)
Lubrication (6)
Engine coolant line sleeve check (7)(6)
Drive system pump oil fi lter check (6) (6)
Hydraulic system oil drain fi lter replacement (6) (6)
Hydraulic system oil suction fi lter replacement (6) (6)
Alternator belt replacement (3)(6)
Cab air fi lter replacement (1)
Injector calibration and cleaning (2)(3)(6)
Climate control system belt replacement (6)
Engine coolant change (3)(6)
Hydraulic system oil change (3)(6)
Brake system check (6)
Hydraulic system pump pressure check (6)
Minor engine overhaul (2)(4)(6)
Major engine overhaul (2)(5)(6)
(1) Or every 6 months
(2) Maintenance to be performed by Lombardini authorised Service Center
(3) Or every 2 years
(4) After 5,000 hours
(5) After 10,000 hours
(6) For the relevant procedure see the Service Manual, at any Nilfi sk-Advance Service Center
(7) Every year, if the machine is not frequently used
(8) If a lower-quality oil is used, change it every 125 hours.