Allied Air Enterprises A93UH Furnace User Manual


 
506501-01Page 4 of 48 Issue 1031
A95UH, A93UH, 95G1UH &92G1UH Gas Furnace
The A95UH/A93UH/95G1UH & 92G1UH Category IV gas
furnace is shipped ready for installation in the upflow or
horizontal position. The furnace is shipped with the bottom
panel in place. The bottom panel must be removed if the
unit is to be installed in horizontal or upflow applications with
bottom return air.
The A95UH/A93UH/95G1UH & 92G1UH can be installed
as either a Direct Vent or a Non-Direct Vent gas central
furnace
The furnace is equipped for installation in natural gas
applications. A conversion kit (ordered separately) is required
for use in propane/LP gas applications.
NOTE: In Direct Vent installations, combustion air is taken
from outdoors and flue gases are discharged outdoors. In
Non-Direct Vent installations, combustion air is taken from
indoors and flue gases are discharged outdoors. See Figure
2 for applications involving roof termination.
Shipping and Packing List
1 - Assembled Gas Furnace
1 - Bag assembly containing the following:
3 - Wire nuts
1 - Snap bushing
1 - Snap Plug
1 - Wire tie
1 - Condensate trap
1 - Condensate trap cap
1 - Condensate trap clamp
1 - 2” diameter debris screen
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.
Please refer to specification sheets for available accessories.
Safety Information
As with any mechanical equipment, personal injury can
result from contact with sharp sheet metal edges. Be
careful when you handle this equipment.
CAUTION
DANGER OF EXPLOSION!
DANGER
There are circumstances in which odorant used with LP/
Propane gas can lose its scent. In case of a leak, LP/
Propane gas will settle close to the floor and may be difficult
to smell. An LP/Propane leak detector should be installed
in all LP applications.
Use only the type of gas approved for use with this furnace.
Refer to unit nameplate.
A95UH/A93UH/95G1UH & 92G1UH units are CSA
International certified to ANSI Z21.47 and CSA 2.3 standards.
Building Codes
In the USA, installation of gas furnaces must conform with
local building codes. In the absence of local codes, units
must be installed according to the current National Fuel Gas
Code (ANSI Z223.1/NFPA 54). The National Fuel Gas Code
is available from the American National Standards
Institute, Inc., 11 West 42nd Street, New Your, NY 10036.
In Canada, installation must conform with current National
Standard of Canada CSA-B149 Natural Gas and Propane
Installation Codes, local plumbing or waste water codes and
other applicable local codes.
In order to ensure proper unit operation in non-direct vent
applications, combustion and ventilation air supply must be
provided according to the current National Fuel Gas Code
or CSA-B149 standard.
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury
or loss of life. Installation and service must be performed
by a licensed professional installer (or equivalent), service
agency or the gas supplier.
WARNING
Figure 2