Alliance Laundry Systems 70444901R3 Humidifier User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Preliminary Information
7
70444901
Restore to Factory Defaults
When the user resets to factory default, the control
resets all of the default values. The control also resets
Machine Cycles #1 through #30. The control will also
reset the following to factory-defaults:
Default Global Settings
Ignition Retries = 3
Temperature Units = Fahrenheit (°F)
High (H) Temperature = 190 (°F)
Medium (M) Temperature = 160 (°F)
Low (L) Temperature = 140 (°F)
Very Low (VL) Temperature = 120 (°F)
Cool Down Temperature = 100 (°F)
Cool Down Time = 2 minutes
Rapid Advance = Disabled
Multi-Segment Cycles = Disabled
Daylight Saving = Enabled
Key Pad Audio = Enabled
End of Cycle Audio = Enabled (5 seconds)
End of Cycle External Signal = Enabled (5 seconds)
Clean Lint Screen Reminder = Off
Display Limit Errors = Disabled
Manual Diagnostics = Enabled
*Manual Programming = Enabled
**Reverse Cylinder Rotate Time = 120 (seconds)
**Reverse Cylinder Stop Time = 6 (seconds)
**Advanced Reversing = Disabled
***Advanced Options for Moisture Dry = Disabled
***Display Moisture Sensor Error = Disabled
*If manual programming is disabled, programming
changes to the control can only be made with an
external communication device. Refer to PC and PDA
Application User Instructions.
**Only available on units equipped with reversing
feature.
***Only available on units equipped with moisture
sensing feature.
Refer to Factory Defaults, Menu section for
information on Restoring Factory Defaults.
Entering Program Mode
1. Press and hold Stop ( ), then Back ( ), then
Up ( ) to enter the programming options.