Alliance Laundry Systems 70444901R3 Humidifier User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
15
70444901
Programming Control
What Can Be Programmed?
This feature allows the owner to program cycle
parameters and other features by using the keypads.
The control must have the Manual Programming Mode
enabled, which is the factory default. This mode can
only be turned OFF and ON by using an external
device. Refer to this section when programming the
control.
For an overview of the programming organization,
refer to the flowcharts on the following pages.
For more advanced users, a quick reference list of the
options available through the programming mode is
located on this page.
NOTE: The codes in the Option Display column of
the Programmable Options List are what will show
in the display when that option is selected.
How to Program a Cycle
1. Press the Up ( ) or Down ( ) keypad to scroll
through the option list.
2. Press Start ( ) to select an option to program.
3. Press the Up ( ) or Down ( ) keypad to change
the value of that option.
4. Press Start ( ) to save the change.
NOTE: Press the Back ( ) keypad to leave the
option without saving any change.
5. After pressing Start ( ), control will go to the
next option in the list.
6. Press Back ( ) keypad to go to Idle Mode.
Programmable Options Available
Option
Number
Option
Display
Description
Default
Value
Value Range
1  Cycle Programming --
a“ Cycle XX (XX represents cycles 1-30) - -
1“ Cycle XX Enable Disable - on/oFF
2“ Cycle XX Type - tinE (Time Dry), Auto (Auto Dry), noist
(Moisture Dry)
3“ Cycle XX Material Type - 0 (Cotton), 1 (Blend), 2 (Bedding), 3
(Delicate), 4 (Synthetic), 5 (Wool)
4“ Cycle XX Time Past Target (minutes) - 0-15
5“ Segment 1 - CXXS11 (Segment 1 Enable/Disable),
CXXS12 (Segment 1 Time),
CXXS13 (Segment 1 Temperature),
CXXS14 (Segment 1 Auto Dry Target
Level),
CXXS15 (Segment 1 Moisture Dry Target
Moisture),
CXXS16 (Segment 1 Reversing Enable/
Disable)
6“ Segment 2 - CXXS21 (Segment 2 Enable/Disable),
CXXS22 (Segment 2 Time),
CXXS23 (Segment 2 Temperature),
CXXS24 (Segment 2 Auto Dry Target
Level),
CXXS25 (Segment 2 Moisture Dry Target
Moisture),
CXXS26 (Segment 2 Reversing Enable/
Disable)