Error Codes
70444901
38
Table 8 (continued)
Display Description
Cause/
Corrective Action

Machine Did Not Reach Expected
Temperature
Check heating connections, cycle power to machine.

Stove Limit 1 Error Remove any lint build-up around thermostat. If problem
persists, replace control or thermostat.

Stove Limit 2 Error Remove any lint build-up around thermostat. If problem
persists, replace control or thermostat.

Cabinet Limit Error Remove any lint build-up around thermostat. If problem
persists, replace control or thermostat.

ICM Lockout Alarm Active

Rotation Sensor Error Check for broken or worn belts. Make sure machine is
not over loaded and check if rotation sensor is working.
If problem persists, replace rotation sensor or control.

DIP Switch Configuration Size Mismatch
Error
Check temperature index harness and dipswitch settings.
If problem persists, replace temperature index harness or
control.

Fan Motor Contactor Error Check signal to control. If problem persists, replace fan
motor or control.

Fan Motor Centrifugal Switch Error Check signal to control. If problem persists, replace fan
motor or control.

Moisture Sensor Error Push Back ( ) keypad to clear the error.
Table 8