Alliance Laundry Systems 70444901R3 Humidifier User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
37
70444901
Error Codes
Following is a list of possible error codes for an
electronic control. Errors beginning with “
” refer to
external device Infra-red communication errors. All
other errors refer to machine errors.
Display Description
Cause/
Corrective Action

Transmission Failure Communication failure. Re-aim external device and try
again.

Device Time-out Communication failure. Re-aim external device and try
again.

Invalid Command Code Incorrect machine type. Before downloading, ensure
data is for current machine type.

Invalid or Out-of-Range Data Incorrect machine type. Before downloading, ensure
data is for current machine type and values entered are
within the minimum and maximum limits.

CRC-16 Error Communication failure. Re-aim external device and try
again.

Framing Error Communication error. Re-aim external device and try
again.

Time-out Exceeded Communication error. Re-aim external device and try
again.

Encryption Error Incorrect machine type. Before downloading, ensure
data is for current machine type.

Invalid Wake-up or Infra-red Disabled Communication failure or infra-red is disabled.
Manually enable infra-red on control or re-aim external
device and try again.

Shorted Thermistor Error Remove any lint build-up around thermistor. If problem
persists, replace control or thermistor.

Open Thermistor Error Remove any lint build-up around thermistor. If problem
persists, replace control or thermistor.

Airflow Switch Error (Switch Fails to
Open At End of Cycle)
Inspect lint screen and ductwork. Once error is cleared,
control will go back to previous mode of operation.

Airflow Switch Error (Switch Does Not
Close After Cycle Starts)
Inspect lint screen and ductwork. Cycle power to
machine (power down, then power up) or push Back ( )
keypad.

Airflow Switch Error (Switch Bounces
During Cycle)
Inspect lint screen and ductwork. Cycle power to
machine (power down, then power up) or push Back ( )
keypad.
Table 8 (continued)