Alliance Laundry Systems 70444901R3 Humidifier User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
12
70444901
Machine Cycle Definition and Operation
There are 30 machine cycles that can be selected and
run. Machine cycles can be modified or made
“unavailable” by manually editing them in Modify
Cycle Menu or by using the PDA to download a
modified machine cycle into the control. Machine
cycles cannot be deleted, but can be made
“unavailable” so that they are not visible from the
Cycle Menu. New machine cycles cannot be created,
but existing machine cycles that have been edited to be
“unavailable” may be re-edited to be available again.
Machine Cycle Operation
When a cycle is run, the control runs the cycle
segment by segment in a sequence. First the control
examines the Cycle Type chosen to determine if it is a
Time Dry, Auto-Dry or Moisture Dry (if equipped)
cycle type. Then the first segment is examined to see if
it is programmed to “
” or “”. If the segment is
programmed to “
”, control skips to the next
segment.
At the start of some machine cycles, the control
displays a Total Remaining Cycle time. This time is
taken from the machine cycles as they are
programmed. The Total Remaining Cycle Time begins
to count down as soon as the cycle is started.
Time Dry Cycle
In this type of cycle, the control will regulate the
temperature and time duration as programmed for the
cycle chosen.
Auto-Dry Cycle
If this type of cycle is selected, the control determines
the cycle time based on the temperature and dryness
level programmed for the cycle chosen.
Moisture Dry Cycle (if equipped)
In this type of cycle, the control checks the
programmed material type, programmed target
moisture content, programmed temperature and the
data received from the moisture sensing system to
achieve the desired results.
Rotation Sensor Equipped
Machines
On machines equipped with a rotation sensor, the
control monitors the rotation sensor to verify the
cylinder is rotating. The control calculates the
cylinder’s RPM. If the RPM drops to zero while the
cylinder is supposed to be rotating, the control will
advance to the Cool Down segment of the cycle and an
error message will be displayed.
To Start a Cycle
1. Press the Up ( ) or Down ( ) keypad to change
cycles.
2. Press Start ( ) to start selected cycle.
NOTE: If door is not closed when the Start ( )
keypad is pressed, display will show “
”.