Alliance Laundry Systems 70444901R3 Humidifier User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Testing Machine and Electronic Control Functions
70444901
32
Machine Configuration Display #3 Test
This option shows the machine configuration values
for the machine capacity.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the Start ( ) keypad. The display
will show “
XXX”, with “XXX” representing the
machine capacity. Refer to Table 6.
To exit Machine Configuration Display #3 Test, press
the Back ( ) keypad. The control will return to the
testing mode.
Airflow Switch Test
This option shows the current state of the airflow
switch.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the Start ( ) keypad. The display
will show “
 ” or “ ”, with “ 
being open and “
 ” being closed.
Switch has to be closed for at least one second or open
for at least one second for a valid change.
To exit Airflow Switch Test, press the Back ( )
keypad. The control will return to the testing mode.
Fan Motor Test
This option shows the fan motor running.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the Start ( ) keypad. The display
will show “
 ” to indicate the fan motor is going
to run.
The test must run for at least six seconds before it can
be exited and off for six seconds before the test can be
run again.
NOTE: This test does not count towards the total
machine run time operation.
To exit Fan Motor Test, press the Back ( ) keypad.
The control will return to the testing mode.
Damper Motor Test
This option shows the damper motor running.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the Start ( ) keypad. The display
will show “
” to indicate the damper motor is
going to run.
The test must run for at least six seconds before it can
be exited and off for six seconds before the test can be
run again.
NOTE: This test does not count towards the total
machine run time operation.
To exit Damper Motor Test, press the Back ( )
keypad. The control will return to the testing mode.
Reverse Motor Test
This option shows the reverse motor running.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the Start ( ) keypad. The display
will show “
” to indicate the reverse motor is
going to run.
The test must run for at least six seconds before it can
be exited and off for six seconds before the test can be
run again.
NOTE: This test does not count towards the total
machine run time operation.
To exit Reverse Motor Test, press the Back ( )
keypad. The control will return to the testing mode.
Value Description
0
Tumbler
17
25 Pound Tumbler
18
30 Pound Tumbler
19
30 Pound Stack Tumbler
20
30 Pound Stack Tumbler – Lower Pocket
21
30 Pound Stack Tumbler – Upper Pocket
22
35 Pound Tumbler
23
45 Pound Stack Tumbler
24
45 Pound Stack Tumbler – Lower Pocket
25
45 Pound Stack Tumbler – Upper Pocket
26
50 Pound Tumbler
27
55 Pound Tumbler
28
75, F75 Pound Tumbler
29
120 Pound Tumbler
30
170 Pound Tumbler
Table 6