Alliance Laundry Systems 70444901R3 Humidifier User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Control Identification
11
70444901
Communication Mode
This mode is entered whenever the control is
communicating with a PDA. Refer to PC and PDA
Application User Instructions.
Cool Down Mode
The control enters the Cool Down Mode after the heat
segment of the cycle is completed. The control turns
the heater off and for steam heated units turns the
damper motor on. The cool down segment will end
once the cool down temperature has been reached or
the programmed cool down time expires, which ever
happens first.
End of Cycle Mode
The control enters End of Cycle Mode after the cool
down segment is finished. The display will toggle
between “
” and “” for one second each
until End of Cycle Mode is exited. If the door has not
been opened or a keypad has not been pressed after
two minutes, the machine will enter Extended Tumble
Mode. This mode is exited when the door is opened or
Stop ( ) keypad is pressed. The control will then
return to Idle Mode.
Extended Tumble Mode
The Extended Tumble Mode has two portions. The
Anti-Wrinkle Tumble is entered two minutes after the
cycle has ended if the door is not opened. The cylinder
will tumble for 30 seconds every two minutes for up to
one hour.
If the door hasn’t been opened and no keys have been
pressed one hour after the Anti-Wrinkle Tumble has
ended, the control increments the Anti-Wrinkle Time
Exceeded audit counter and enters the Delayed
Tumble. The cylinder will tumble for two minutes
every 60 minutes for up to 18 hours.
Reversing Mode (reversing models only)
Models equipped with the reversing feature will rotate
in the forward direction, pause, rotate in the reverse
direction and then pause for programmable times and
segments of the cycle. Factory default rotate time is
120 seconds and reversing stop time is 6 seconds for
all cycles with reversing enabled.
Entering Diagnostic Mode From Idle Mode
When entered from the Idle Mode, the control will be
running a test selected by the user via keypad presses
or communication with a device.