Table 4: Unit Dimensions
Unit Size
Dimensions
“A” “B”
024 33-1/2 18-1/4
036, 048 41-1/2 23-1/8
Table 5: Unit Clearances
1
2
1. A 1" clearance must be provided between any combustible material and the supply air duct work.
2. The products of combustion must not be allowed to accumulate within a confined space and recirculate.
Direction
Distance
(in.)
Direction
Distance
(in.)
Top
3
3. Units must be installed outdoors. Over hanging structure or shrubs should not obscure condenser air
discharge outlet.
36 Right 12
Front 36 Left 24
Rear 0 Bottom
4
4. Units may be installed on combustable floors made from wood or class A, B or C roof covering
materials.
0