TABLE 2: RATINGS COOLING/GAS HEATING
MODEL
DNH
NET COOLING CAPACITY
1
SOUND
RATING
(dbels)
2
GAS HEAT CAPACITY / EFFICIENCIES
MBH
SEER
3
INPUT
(MBH)
OUTPUT
(MBH)
AFUE
4
(%)
NUMBER OF
BURNERS
TEMP.
RISE
(°F) RANGE
030N03625 28.0 12.0 80 45 36 80.2 2 25 - 55
030N03646 28.0 12.0 80 45 36 80.2 2 25 - 55
030N05625 28.0 12.0 80 70 56 80.2 3 30 - 60
030N05646 28.0 12.0 80 70 56 80.2 3 30 - 60
036N03625 36.0 12.0 81 45 36 80.4 2 25 - 55
036N03646 36.0 12.0 81 45 36 80.4 2 25 - 55
036N05625 36.0 12.0 81 70 56 80.2 3 25 - 55
036N05646 36.0 12.0 81 70 56 80.2 3 25 - 55
036N07225 36.0 12.0 81 90 72 80.1 4 30 - 60
036N07246 36.0 12.0 81 90 72 80.1 4 30 - 60
042N06525 42.0 12.0 80 80 64 80.6 3 25 - 55
042N06546 42.0 12.0 80 80 64 80.6 3 25 - 55
042N09025 42.0 12.0 80 108 87 80.8 4 45 - 75
042N09046 42.0 12.0 80 108 87 80.8 4 45 - 75
048N06525 48.0 12.0 84 80 64 80.8 3 25 - 55
048N06546 48.0 12.0 84 80 64 80.8 3 25 - 55
048N09025 48.0 12.0 84 108 86 80.6 4 35 - 65
048N09046 48.0 12.0 84 108 86 80.6 4 35 - 65
048N11025 48.0 12.0 84 135 107 80.5 5 45 - 75
048N11046 48.0 12.0 84 135 107 80.5 5 45 - 75
060N06525 59.0 12.0 84 80 64 80.7 3 25 - 55
060N06546 59.0 12.0 84 80 64 80.7 3 25 - 55
060N09025 59.0 12.0 84 108 87 80.9 4 35 - 65
060N09046 59.0 12.0 84 108 87 80.9 4 35 - 65
060N11025 59.0 12.0 84 135 107 80.2 5 45 - 75
060N11046 59.0 12.0 84 135 107 80.2 5 45 - 75
1. Net Cooling Capacity = ARI 210 standard rating conditions.
2. (dbels) = ARI 270-95
3. Seasonal Energy Efficiency Ratio - the total cooling output in BTU’s during a normal annual usage period for cooling divided by the
total electric power input in watt-hours during the same period.
4. AFUE = Annual Fuel Utilization Efficiency.