Door Arm Hookup
Align hole in the door arm with holes in operator bracket tabs, as shown. Attach with 5/16” x
1-3/4” cotter pin and cotter ring, as shown.
Drawbar operator
bracket tabs
Cotter
ring
5/16” x 1-3/4”
Clevis pin
Door arm
Cotter ring
5/16” x 1-3/4”
Clevis pin
Inside Lock
Install the inside lock on the second section of the door. Secure the lock to the section with
(4) 1/4” - 20 x 11/16” self drilling screws. Square the lock assembly with the door section,
and align with the square hole in the vertical track. The inside lock should be spaced ap-
proximately 1/8” away from the section edge.
Important : Inside lock(s) must be removed or made inoperative in the unlocked position if an
operator is installed on this door.
(4) 1/4”-20 x 11/16”
Self drilling screws
Square hole in
vertical track
Second section
Inside lock
End stile
1/8”
Pull Down Rope
WARNINGWARNING
DO NOT INSTALL PULL DOWN ROPE ON DOORS WITH OPERATORS.
CHILDREN MAY BECOME ENTANGLED IN THE ROPE CAUSING SEVERE OR
FATAL INJURY.
Measure and mark the jamb approximately 48” to 50” (1220 to 1270 mm) from floor on the
right or left side of jamb. Drill 1/8” pilot hole for no. 6 screw eye. Tie the pull down rope to the
no. 6 screw eye and to the bottom corner bracket, as shown.
Typical bottom
corner bracket
Pull down
rope
No. 6 Screw eye
Pull
down
rope
48” to 50”
From floor
Interior Lite Caulking
NOTE: After your door is installed, field caulking is required for lited sections in applica-
tions subjected to heavy frost and or condensation forming on the inside of the windows.
Not caulking the inside of the lite frames in these applications can subject the door to high
amounts of moisture on the interior and may damage the door. Use acrylic latex plus silicone
caulk.
First, caulk the perimeter of the inside of the lite frames to the glass located in the top sec-
tion. Next, caulk the lite frames to the top section surface at the horizontal top edge only.
IMPORTANT: NOT CAULKING YOUR DOOR MAY VOID THE WARRANTY.
Caulk
Typical lite frames shown
Top section
Caulk
Caulk
Caulk
18
Optional Installation