Before you clean the fi lters, you
must close the compressed air
input valve and release the pres-
sure contained inside the pump
and the pipes attached to it.
This pump has one fi lter inside the
suction pipe and another inside
the delivery circuit.
ALL FILTERS MUST BE CLEANED
DAILY.
IT IS ALSO NECESSARY TO CLEAN
THEM WHEN USING A DIFFERENT
COLOUR PAINT FROM THE ONE
PREVIOUSLY USED.
To clean the suction pipe (M) fi lter
undo the spring, take out the fi lte-
ring disk, leave it in some solvent,
brush it and spray it with compres-
sed air.
To clean the antipulsation fi lter,
unscrew the plastic ring nut (O)
from the reducer body (P), lift the
cup (Q) paying attention to the
PTFE gasket on the edge. Remove
the fi lter (R ) from the seat (S), pul-
ling it upward, since it has a very
simple fi xing (clip).
Plunge the fi ltering cartridge into
the solvent, then brush and blow
it. Make sure to clean also the fi lter
inner side with solvent and blow it
with compressed air if necessary.
To reassemble the fi lter, push it on
the seat until hearing the fi xing
clip;
do not push the fi lter any further,
to avoid damaging it. Reposition
the cup making sure the gasket is
in the perfect position, then screw
the ring nut.
6.3 FILTER CLEANING OPERATIONS