Wagner SprayTech B_04234 Water Pump User Manual


 
41
B_04243
A5
X
B_04247
9
1
5
OPERATING MANUAL
VERSION 10/2013
ORDER NUMBER DOC 2303675
Vent
Procedure:
1 Turn the pump upside down. Remove the threaded plug (5).
2 Slowly start up (vent) the pump until no air bubbles appear from the oil suction  tting.
3 Oil level A in the oil tank has to be within the speci ed markings (X).
4 Screw in threaded plug (5) and tighten with 2 Nm; 1.5 lbft.
5 Mount piston cover (1) and hood with casing.
6 The device is ready for operation again.