Wagner SprayTech B_04234 Water Pump User Manual


 
38
B_04241
1
B_04242
B_04243
A5
X
OPERATING MANUAL
VERSION 10/2013
ORDER NUMBER DOC 2303675
9.3 HYDRAULIC STAGE MAINTENANCE
9.3.1 CHECKING THE OIL LEVEL
Dismount the device onto a stand as shown in the picture and turn it upside down.
Observe the  ll level marking (X) on the oil tank.
1 Start up the pump for a short time without any product.
2 Then read oil level A.
Dismount the device onto a stand as shown in the picture and
turn it upside down.
Observe the  ll level marking (X) on the oil tank.
Oil level A in the oil tank (1) has to be within the speci ed markings (X).
If the level deviates from these markings, the hydraulic oil must be
topped up.
Procedure:
1 Unscrew and remove threaded plug (5).
2 Top up oil to level A = middle of marking X.
3 Start up the pump for a short time without any product and check for air bubbles.
4 Screw in threaded plug (5) and tighten with 2 Nm; 1.5 lbft.
Using hydraulic oil
Using the wrong hydraulic oil can cause a malfunction.
Use only original hydraulic oil - Wagner Order No. 322912 (250 ml or 15 cu inch).
NOTICE
max.
min.