Wagner SprayTech B_04234 Water Pump User Manual


 
26
"?
2MAX-7
OPERATING MANUAL
VERSION 10/2013
ORDER NUMBER DOC 2303675
6.1.2 GROUNDING
Grounding scheme (example)
Pump
Paint tank
Work piece
Conveyor
Spraying stand
Floor static dissipative
Discharge of electrostatically charged components in atmospheres
containing solvents!
Explosion hazard from electrostatic sparks.
Only use a damp cloth to clean the piston pump.
WARNING
Heavy paint mist if grounding is insu cient!
Danger of poisoning.
Insu cient paint application quality.
Ground all device components.
Ground the work pieces to be coated.
WARNING